Skip to main content

Table 3 Comparison of methods on decomposition accuracy and efficiency

From: Cavitation Diagnostics Based on Self-Tuning VMD for Fluid Machinery with Low-SNR Conditions

Signal

Method

\({c}_{{u}_{1}{(x}_{1}+{x}_{2})}\)(%)

\({c}_{{u}_{2}{(c}_{1}+{c}_{2})}\)(%)

Time (s)

f without noise

SVMD

99.89

98.54

1166

SSA-VMD

99.74

97.42

13123

CEEMD

92.96

93.74

3.4

OVMD

99.89

98.54

16580

SK

0.02

21.29

2.4

f with noise

SNR=0 dB

SVMD

94.51

88.12

3326

SSA-VMD

93.92

82.16

15682

CEEMD

62.82

63. 1

3.2

OVMD

94.51

88.59

15965

SK

0

18.05

2.9

f with noise

SNR=−5 dB

SVMD

84

79.9

4582

SSA-VMD

82.41

65.47

25246

CEEMD

48.93

42.31

4.1

OVMD

84.06

81.07

21584

SK

0

12.3

3.4

f with noise

SNR=−10 dB

SVMD

63.14

72.02

5020

SSA-VMD

57.76

45.84

30036

CEEMD

29.52

27.19

5.5

OVMD

63.15

72.03

24364

 

SK

60.95

0

3.6