Table 3 Averaged successful rates (SR) of ten runs three-fold cross validation in terms of static air-gap eccentricity fault diagnosis using SVM (%)

From: An Intelligent Harmonic Synthesis Technique for Air-Gap Eccentricity Fault Diagnosis in Induction Motors

Load level

0

20

50

70

100

PSD training SR

69.71

65.84

68.23

65.38

60.46

PSD test SR

65.97

61.49

65.52

61.66

53.57

HHT training SR

99.26

72.30

53.20

52.20

77.27

HHT test SR

98.41

71.59

48.76

51.20

74.99

CHS training SR

96.18

81.47

96.68

96.14

96.17

CHS test SR

94.54

78.92

95.79

94.73

95.77

HS training SR

100

100

99.56

100

97.87

HS test SR

100

100

99.20

100

97.28