Skip to main content

Table 2 Characteristics of two actual degradation paths #1 and #2

From: Integrated Equipment Health Prognosis Considering Crack Initiation Time Uncertainty and Random Shock

Path #

\(m\)

\(t_{0}\) / cycles

Failure time / cycles

Inspection interval / cycles

1

1.6

1.7\(\times 1 0^{6}\)

4215500

3\(\times 1 0^{5}\)

2

1.6

2.3\(\times 1 0^{6}\)

4815500

5\(\times 1 0^{5}\)