Skip to main content

TableĀ 7 Measured values and the calculated value errors of the laboratory-calibrated coefficients under multiple working conditions (Mse1)

From: Analysis of the Load-Stress Response Characteristics of the Bogie Frame in Intercity Electric Multiple Unit

Error Measuring point
D13 D15 D26 D34 D46 D48 D55 D57
Entering or departing the depot calculation error 0.09 1.17 0.80 1.02 0.86 1.52 0.21 0.99
Upgoing line working condition calculation error 0.29 1.96 1.38 1.59 1.74 1.59 0.73 1.14
Downgoing line working condition calculation error 0.31 1.89 1.43 1.66 1.84 1.57 0.71 1.12
Heavy vehicle working condition calculation error 0.30 2.13 1.81 2.00 2.36 1.81 0.95 1.35