Table 5 Range analysis table of two performance indexes

From: Parameters Sensitivity Characteristics of Highly Integrated Valve-Controlled Cylinder Force Control System

Performance indexes Amplitude attenuation \(\varPhi\) (N) Phase lag \(\psi\) (10‒2(°))
P s f A P s f A
Factors Exp. Sim. Exp. Sim. Exp. Sim. Exp. Sim. Exp. Sim. Exp. Sim.
k 1 70.0 79.0 30.9 11.9 27.1 11.4 15.7 12.1 5.9 3.8 10.4 7.9
k 2 33.9 20.6 45.1 26.3 48.7 27.0 9.5 7.9 10.3 7.7 12.3 8.3
k 3 28.7 15.8 56.7 77.2 56.9 77.1 10.0 6.3 18.9 14.9 12.4 10.2
R 41.3 63.2 25.8 65.3 29.8 65.7 6.2 5.8 13.0 11.1 2.0 2.3