Table 3 Details of the hydraulics system

From: Noise Reduction of an Axial Piston Pump by Valve Plate Optimization

No.

Description

Detail

1

Inlet pressure sensor

NS-I1, 0-1 MPa, accuracy 0.3% FS

2

Inlet temperature sensor

SBWR/Z, range -25-120 °C, accuracy 0.25% FS

3

Electric motor

Y315L2-2, speed range 300-2980 r/min

4

Shaft speed sensor

JC2C, range 0-4000 r/min, accuracy ± 1 r/min

5

Shaft torque sensor

JC2C, range 0-2000 Nm, 0.2 class accuracy

6

Outlet pressure sensor

NSI1, range 0-40 MPa, accuracy 0.3% FS

7

Outlet flow meter

LC-A50, range 0-400 L/min, 0.2 class accuracy

8

Pressure relief valve

DBDH6P1X400

9

Test pump

71 cc/rev