Skip to main content

Table 3 Configurations and simulation results in DOE

From: Performance Analysis and Improvement of Flat Torque Converters Using DOE Method

Case number

Factors

Responses

Turbine inlet angle \(\beta_{\text{T1}}\) (°)

Turbine outlet angle \(\beta_{\text{T2}}\) (°)

Impeller inlet angle \(\beta_{\text{I1}}\) (°)

Impeller outlet angle \(\beta_{\text{I2}}\) (°)

Stator inlet angle \(\beta_{\text{S1}}\) (°)

Stator outlet angle \(\beta_{\text{S2}}\) (°)

Stall torque ratio \(Tr_{0}\)

Peak efficiency \(\eta^{*}\) (%)

1

28

138

125

44

91.5

15

1.7996

80.96

2

28

141

128

47

94.5

18

1.8055

81.65

3

28

144

131

50

97.5

21

1.8359

82.98

4

28

147

134

53

100.5

24

1.8055

81.23

5

28

150

137

56

103.5

27

1.7852

80.36

6

31

138

128

50

100.5

27

1.7621

78.34

7

31

141

131

53

103.5

15

1.7961

79.17

8

31

144

134

56

91.5

18

1.8014

80.29

9

31

147

137

44

94.5

21

1.8147

80.37

10

31

150

125

47

97.5

24

1.8199

80.11

11

34

138

131

56

94.5

24

1.7699

77.19

12

34

141

134

44

97.5

27

1.7996

79.82

13

34

144

137

47

100.5

15

1.8269

82.36

14

34

147

125

50

103.5

18

1.8455

82.76

15

34

150

128

53

91.5

21

1.8347

83.21

16

37

138

134

47

103.5

21

1.7806

79.24

17

37

141

137

50

91.5

24

1.7982

81.25

18

37

144

125

53

94.5

27

1.7717

79.53

19

37

147

128

56

97.5

15

1.8426

83.24

20

37

150

131

44

100.5

18

1.8364

81.71

21

40

138

137

53

97.5

18

1.7998

80.21

22

40

141

125

56

100.5

21

1.7516

77.59

23

40

144

128

44

103.5

24

1.7817

79.24

24

40

147

131

47

91.5

27

1.7995

78.47

25

40

150

134

50

94.5

15

1.8106

81.56