From: Performance Analysis and Improvement of Flat Torque Converters Using DOE Method
Case number | Factors | Responses | ||||||
---|---|---|---|---|---|---|---|---|
Turbine inlet angle \(\beta_{\text{T1}}\) (°) | Turbine outlet angle \(\beta_{\text{T2}}\) (°) | Impeller inlet angle \(\beta_{\text{I1}}\) (°) | Impeller outlet angle \(\beta_{\text{I2}}\) (°) | Stator inlet angle \(\beta_{\text{S1}}\) (°) | Stator outlet angle \(\beta_{\text{S2}}\) (°) | Stall torque ratio \(Tr_{0}\) | Peak efficiency \(\eta^{*}\) (%) | |
1 | 28 | 138 | 125 | 44 | 91.5 | 15 | 1.7996 | 80.96 |
2 | 28 | 141 | 128 | 47 | 94.5 | 18 | 1.8055 | 81.65 |
3 | 28 | 144 | 131 | 50 | 97.5 | 21 | 1.8359 | 82.98 |
4 | 28 | 147 | 134 | 53 | 100.5 | 24 | 1.8055 | 81.23 |
5 | 28 | 150 | 137 | 56 | 103.5 | 27 | 1.7852 | 80.36 |
6 | 31 | 138 | 128 | 50 | 100.5 | 27 | 1.7621 | 78.34 |
7 | 31 | 141 | 131 | 53 | 103.5 | 15 | 1.7961 | 79.17 |
8 | 31 | 144 | 134 | 56 | 91.5 | 18 | 1.8014 | 80.29 |
9 | 31 | 147 | 137 | 44 | 94.5 | 21 | 1.8147 | 80.37 |
10 | 31 | 150 | 125 | 47 | 97.5 | 24 | 1.8199 | 80.11 |
11 | 34 | 138 | 131 | 56 | 94.5 | 24 | 1.7699 | 77.19 |
12 | 34 | 141 | 134 | 44 | 97.5 | 27 | 1.7996 | 79.82 |
13 | 34 | 144 | 137 | 47 | 100.5 | 15 | 1.8269 | 82.36 |
14 | 34 | 147 | 125 | 50 | 103.5 | 18 | 1.8455 | 82.76 |
15 | 34 | 150 | 128 | 53 | 91.5 | 21 | 1.8347 | 83.21 |
16 | 37 | 138 | 134 | 47 | 103.5 | 21 | 1.7806 | 79.24 |
17 | 37 | 141 | 137 | 50 | 91.5 | 24 | 1.7982 | 81.25 |
18 | 37 | 144 | 125 | 53 | 94.5 | 27 | 1.7717 | 79.53 |
19 | 37 | 147 | 128 | 56 | 97.5 | 15 | 1.8426 | 83.24 |
20 | 37 | 150 | 131 | 44 | 100.5 | 18 | 1.8364 | 81.71 |
21 | 40 | 138 | 137 | 53 | 97.5 | 18 | 1.7998 | 80.21 |
22 | 40 | 141 | 125 | 56 | 100.5 | 21 | 1.7516 | 77.59 |
23 | 40 | 144 | 128 | 44 | 103.5 | 24 | 1.7817 | 79.24 |
24 | 40 | 147 | 131 | 47 | 91.5 | 27 | 1.7995 | 78.47 |
25 | 40 | 150 | 134 | 50 | 94.5 | 15 | 1.8106 | 81.56 |