Table 1 Parameters employed in the thermal analysis

From: Numerical Study on the Stress–Strain Cycle of Thermal Self-Compressing Bonding

Parameter

Value

Beam voltage Ub (kV)

150

Beam current Ib (mA)

1.9

Heating time tH (s)

300

Heat efficiency η

0.95

Length of the heat source l (mm)

50

The effective radius of the heat source R (mm)

4