Skip to main content

Table 1 Equivalent attenuation coefficient of EC in the test samples of various thicknesses at different frequencies

From: Characteristics of Eddy Current Attenuation and Thickness Measurement of Metallic Plate

Plate thickness (mm)

Equivalent attenuation coefficient \( \tilde{\alpha } \)

1 kHz

3 kHz

10 kHz

30 kHz

1

0.4995

0.5409

0.6684

1.2400

2

0.5011

0.5886

0.9211

1.6070

3

0.5054

0.6342

1.0080

1.6170

5

0.5191

0.6776

1.0200

1.6180

inf.

0.5283

0.6810

1.0200

1.6180