Skip to main content

Table 5 Main comparison between theoretical and test values of a0max (L) (ps = 1 MPa) (mm)

From: Simple Push-Type Wave Generating Method Using Digital Rotary Valve Control

f (Hz)

xv

1 mm

1.5 mm

2 mm

Theoretical results

Test results

Theoretical results

Test results

Theoretical results

Test results

1

48 (151)

40 (150)

55 (151)

48 (154)

64 (151)

60 (154)

1.6

32 (61)

30 (62)

36 (61)

33 (62)

42 (61)

45 (63)

2

24 (39)

19 (41)

27 (39)

23 (41)

30 (39)

26 (40)