Skip to main content

Table 5 Main comparison between theoretical and test values of a0max (L) (ps = 1 MPa) (mm)

From: Simple Push-Type Wave Generating Method Using Digital Rotary Valve Control

f (Hz)xv
1 mm1.5 mm2 mm
Theoretical resultsTest resultsTheoretical resultsTest resultsTheoretical resultsTest results
148 (151)40 (150)55 (151)48 (154)64 (151)60 (154)
1.632 (61)30 (62)36 (61)33 (62)42 (61)45 (63)
224 (39)19 (41)27 (39)23 (41)30 (39)26 (40)