Skip to main content

Table 1 Specifications of experimental setup

From: Flow Control for a Two-Stage Proportional Valve with Hydraulic Position Feedback

Device

Producer

Model number

Specification

 

Main valve

Vickers

EPV16

  

Pilot valve

Vickers

TG4V

  

Variable pump

Bosch Rexroth

SYDFEE-20/100R

Rated pressure (MPa)

28

Rated speed (r/min)

1450

Maximum displacement (mL/r)

100

Pressure sensor

Kistler

4260A200

Full scale (MPa)

20

Maximum frequency response (Hz)

2000

Measurement error

0.05% FS

Flow meter

Parker

SCVF-150

Full scale (L/min)

20

Response time (ms)

150

Measurement error

0.5% FS

Flow meter

Parker

SCVF-15

Full scale (L/min)

15

Response time (ms)

20

Measurement error

0.5% FS