Skip to main content

Table 5 Calculation results before and after optimization

From: Experimental Investigation and Optimization Design of Multi-Support Pipeline System

Variable

D1 (mm)

D3 (mm)

D4 (mm)

D5 (mm)

First-order frequency (Hz)

Maximum stress (MPa)

Maximum acceleration (g)

Initial

350

950

1250

1550

216

2.47

2.87

Optimal

322.97

891.58

1218.1

1503.8

248

1.91

1.70