Table 2 Results of flow step response experiment under stable backpressure

From: Investigation into the Independent Metering Control Performance of a Twin Spools Valve with Switching Technology-controlled Pilot Stage

Flow step (L/min) Indicator TSVSP simulation TSVSP experiment Experiment in Ref. [[20]]
20–30 Flow stabilization time(ms) 100 120 90
Pressure recovery time(ms) 80 140 70
30–40 Flow stabilization time(ms) 90 100 90
Pressure recovery time(ms) 40 60 100