Skip to main content

Table 2 Main parameters and size of the experimental platform

From: Influence of Novel Redirector with Bypass Damping on the Performance of Load-Sensing Steering System

Definition Parameters
Pump Displacement: 80 cc/rev
Max. rotation speed: 2350 r/min
Data acquisition Signal: 1–5 V, Accuracy: 0.02%, Channels: 8
Pressure sensor Range: 0–60/40 MPa, Accuracy: 0.1%, Voltage: 12 VDC
Flow meter Range: 300 L/min, Accuracy: 1%
Tachometer Range: 0–3000 r/min, Accuracy: 1%