Skip to main content

Table 1 Specific information for the experimental data

From: Lifetime and Aging Degradation Prognostics for Lithium-ion Battery Packs Based on a Cell to Pack Method

Battery Current (C) Temperature (℃) Capacity range (Ah) Lifetime (cycles)
Cell#1 0.5‒0.5 35 103.755‒85.215 646
Cell#2 0.5‒0.5 35 102.553‒77.524 810
Cell#3 0.5‒0.5 35 102.750‒71.433 744
Cell#4 1.0‒1.0 25 103.040‒70.954 495
Cell#5 0.5‒0.5 55 102.813‒71.457 409
Cell#6 0.5‒0.5 55 103.435‒72.680 389
Cell#7 1.0‒1.0 55 102.910‒70.784 314
Pack 0.5‒0.5 35 100.294‒77.031 415