From: Heat Transfer Performance and Structural Optimization of a Novel Micro-channel Heat Sink
Test number | Honeycomb type A | Distance between honeycombs B(mm) | Honeycomb depth C(mm) | Circum-radius of polygons D (mm) | Blank column | Simulated results T (℃) |
---|---|---|---|---|---|---|
1# | 1 | 1 | 1 | 1 | 1 | 81.13 |
2# | 1 | 2 | 2 | 2 | 2 | 82.05 |
3# | 1 | 3 | 3 | 3 | 3 | 84.87 |
4# | 1 | 4 | 4 | 4 | 4 | 87.39 |
5# | 2 | 1 | 2 | 3 | 4 | 82.77 |
6# | 2 | 2 | 1 | 4 | 3 | 80.36 |
7# | 2 | 3 | 4 | 1 | 2 | 83.58 |
8# | 2 | 4 | 3 | 2 | 1 | 83.09 |
9# | 3 | 1 | 3 | 4 | 2 | 79.55 |
10# | 3 | 2 | 4 | 3 | 1 | 80.91 |
11# | 3 | 3 | 1 | 2 | 4 | 84.57 |
12# | 3 | 4 | 2 | 1 | 3 | 87.05 |
13# | 4 | 1 | 4 | 2 | 3 | 80.32 |
14# | 4 | 2 | 3 | 1 | 4 | 80.67 |
15# | 4 | 3 | 2 | 4 | 1 | 81.83 |
16# | 4 | 4 | 1 | 3 | 2 | 81.46 |
S1 | 335.44 | 323.77 | 327.52 | 332.43 | Â | Â |
S2 | 329.8 | 323.99 | 333.7 | 330.03 | Â | Â |
S3 | 332.08 | 334.85 | 328.18 | 330.01 | Â | Â |
S4 | 324.28 | 338.99 | 332.2 | 329.13 | Â | Â |
s1 | 83.86 | 80.94 | 81.88 | 83.11 | Â | Â |
s2 | 82.45 | 81.00 | 83.43 | 82.51 | Â | Â |
s3 | 83.02 | 83.71 | 82.05 | 82.50 | Â | Â |
s4 | 81.07 | 84.75 | 83.05 | 82.28 | Â | Â |
R | 2.79 | 3.81 | 1.55 | 0.83 | Â | Â |
factors | B→A→C→D |