From: Analytical Modelling and Experiment of Novel Rotary Electro-Mechanical Converter with Negative Feedback Mechanism for 2D Valve
\(i\)(A)
0
0.5
1
1.5
\(T\)(N·m) (\(\theta\) = 1.5°)
Analytical
0.105
0.223
0.349
0.482
FEM
0.095
0.222
0.360
0.476
Experimental
0.090
0.212
0.339
0.480