Skip to main content

Table 4 Accuracy of linear, separable and complete quadratic reciprocal variables RSM models for the 2-bar truss structure problem

From: Multivariate Rational Response Surface Approximation of Nodal Displacements of Truss Structures

Evaluation standards

Linear form

Separable quadratic form

Complete quadratic form

Multiple fitting coefficient \(R^{2}\)

1

1

1

Modified multiple fitting coefficient \(R_{\text{adj}}^{2}\)

1

1

1

Maximum relative error ζmax/%

5.78 × 10−14

1.68 × 10−12

1.13 × 10−12

Minimum relative error ζmin/%

1.14 × 10−14

1.09 × 10−12

5.22 × 10−13

Average relative error ζavg/%

3.38 × 10−14

1.40 × 10−12

8.21 × 10−13