Skip to main content

Table 5 Receiver pressures after modification

From: Analysis of the Internal Characteristics of a Deflector Jet Servo Valve

Displacement (mm)

Left receiver (MPa)

Right receiver (MPa)

0.04

3.9

10.3

0.03

4.1

8.7

0.02

4.5

7.3

0.01

4.9

6.3

0

5.5

5.5

− 0.01

6.3

4.9

− 0.02

7.3

4.5

− 0.03

8.7

4.1

− 0.04

10.3

3.9