Skip to main content

Table 3 Keys of testing the circuit components

From: Methods to Evaluate and Measure Power of Pneumatic System and Their Applications

Reference letter

Relevant subclause (s)

Description

Comments

A

Adjustable pressure regulator

 

B

Shut-off valve

Preferably with straight flow path

C

Upstream flow meter

 

D

6.5

Upstream temperature-measuring tube

 

E

Upstream temperature-measuring instrument

Sensor located on axis of D at distance > 3d upstream of the end of D

F

6.5

Transition connector upstream side

 

G

Upstream pressure gauge or transducer

 

H

Component under test

 

I

Downstream gauge meter or transducer

 

J

6.5

Transition connector downstream side

 

K

Downstream temperature-measuring instrument

 

L

6.5

Downstream temperature-measuring tube

 

M

Downstream flow meter

 

N

Flow control valve

With a flow-rate capacity greater than the component under test

O1

6.5

Upstream pressure-measuring tube

Apply to tube or thread connector

O2

6.5

Downstream pressure-measuring tube

Apply to tube or thread connector

  1. Items A to M are essential and the remaining N, O are chosen by the person conducting the test to suit the prevailing conditions