Skip to main content

Table 1 Results of backpressure step response test under stable flow

From: Investigation into the Independent Metering Control Performance of a Twin Spools Valve with Switching Technology-controlled Pilot Stage

Pressure step(MPa) Indicator TSVSP simulation TSVSP experiment Experiment in Ref. [[20]]
1–2 Pressure stabilization time(ms) 100 120 110
Pressure overshoot
(MPa)
0 6.1 5
Flow recovery time(ms) 80 80 170
2–3 Pressure stabilization time(ms) 60 60 50
Pressure overshoot (MPa) 0 4.7 4.8
Flow recovery time(ms) 100 180 500