Skip to main content

Table 5 Time consumption and CPRs of different methods for tooth broken fault signal

From: Incipient Gear Fault Detection Using Adaptive Impulsive Wavelet Filter Based on Spectral Negentropy

  SNM CCM KM
Time Consumption(s) 274.8 1951.9 1726.5
CPRs 0.7178 0.3217 0.4579