Table 9 Cavitation numbers under various charging conditions

From: Influence of Charging Oil Condition on Torque Converter Cavitation Characteristics

Charging position Charge pressure (MPa) Mass flow rate(kg· s-1) Cavitation number
S-P clearance 0.3 330.8 3.343
S-P clearance 0.6 386.1 4.909
S-P clearance 0.9 407.4 6.614
P-T clearance 0.6 311.2 7.556
T-S clearance 0.6 390.1 4.811