Skip to main content

Table 5 Comparison of magnetic flux densities under different currents and rotation angles

From: Analytical Modelling and Experiment of Novel Rotary Electro-Mechanical Converter with Negative Feedback Mechanism for 2D Valve

\(i\)(A)

 

0

0.5

1

1.5

\({B}_{1}\)(T) (\(\theta\) = 1°)

Analytical

0.170

0.225

0.280

0.335

FEM

0.171

0.224

0.277

0.329

Experimental

0.162

0.210

0.260

0.312

\({B}_{2}\)(T) (\(\theta\)=1°)

FEM

0.112

0.065

0.016

−0.030

Analytical

0.104

0.055

0.005

−0.045

Experimental

0.102

0.063

0.020

−0.022