From: Analytical Modelling and Experiment of Novel Rotary Electro-Mechanical Converter with Negative Feedback Mechanism for 2D Valve
\(i\)(A)
0
0.5
1
1.5
\(T\)(N·m) (\(z\) = 0.8 mm)
Analytical
− 0.142
− 0.024
0.083
0.181
FEM
− 0.162
− 0.028
0.086
0.178
Experimental
− 0.165
− 0.039
0.075
0.163