Skip to main content

Table 6 Parameters set for sinusoidal signal

From: Nonlinear Control of Magnetically Coupled Rodless Cylinder Position Servo System

Physical significance

Symbol

Value

Learning rate

\(lr\)

0.2

Factor of momentum

\(\beta\)

0.06

Number of neurons

\(nn\)

6

Initial PID parameter

\(K_{{\text{p}}}\)

30

\(K_{{\text{i}}}\)

0.00001

\(K_{{\text{d}}}\)

0.0001

PID parameter learning rate

\(lr\_K_{{\text{p}}}\)

0.4

\(lr\_K_{{\text{i}}}\)

0.02

\(lr\_K_{{\text{d}}}\)

0.02