Skip to main content

Table 3 Variation of the vortex size as function of the slots inclination angle for Re = 4 × 104

From: Effect of an Inclined Slots on the Power Consumption and Vortices Size in a Rushton Turbine Agitated Tank

Vessel

Unbaffled vessel

Baffled vessel

Vessel with slots of F/D = 1/5

Inclination angle

α = 0°

α = 10°

α = 22.5°

α = 32.5°

Direction + ω

0.667

0.434

0.468

0.479

0.538

0.570

Direction − ω

0.667

0.434

0.468

0.440

0.427

0.391