From: High-Efficiency Dynamic Scanning Strategy for Powder Bed Fusion by Controlling Temperature Field of the Heat-Affected Zone
Parameter
Value
Field angle (°)
90 × 73
Measuring temperature range (℃)
0–350 or 200–1200
Measurement frequency (Hz)
9
Resolution
320 × 240
Measurement accuracy (%)
± 2